Required Digi-Star Indicator Settings for Correct RD4100/J904 Serial Display Operation (Power Y-Harness Only)
If Sign Does Not Work Follow These Instructions
Digi-Star J-904 Serial Port Indicators (Power Y-Harness Only)
1906-0404 - 4” RD4100
USE THE METHOD BELOW IF THE INDICATOR IS AN EZ400, EZ2000, OR EZ2400
Push and hold NET GROSS and ON until it scrolls, press select or net for Menu’s 1,2,3,4,5, etc.
Press NET GROSS or SELECT until Menu 2 appears.
Press ON until SCOREM appears.
Press NET GROSS or SELECT until 3 comes up.
Press ON until COMIN appears.
Press NET GROSS OR SELECT until DOWNLD appears.
Press ON repeatedly until EXIT appears.
Press ON once more to return to weight mode.
USE THE METHOD BELOW IF THE INDICATOR IS AN EZ3200, EZ3400, ES3500 OR ST3400
Key in 213.
Press Select until 22 Appears
Press Enter
Key in 215.
Press Select until EZ2CMD Appears
Press Enter
IMPORTANT!! If 4” remote still doesn’t work change the ScoreM to 23.
Related Articles
Required Digi-star Indicator Settings for Correct RD4100/Serial Display Operation.
Required Digi-star Indicator Settings for Correct RD4100/Serial Display Operation.Serial Port Instructions only USE THE METHOD BELOW IF THE INDICATOR IS A EZ400, GT400, OR EZ2500V 1) Push and hold NET GROSS or FIELD and ON until it scrolls, press ...
Required Digi-Star Indicator Settings for Correct RD4100/Remote Display Operation
Digi-Star Indicator RD-4100 Settings/Remote Port Remote Port Instructions Only If indicator has keypad please use Direct Access Numbers USE THE METHOD BELOW IF THE INDICATOR IS AN EZ2000, EZ2400, OR EZ2500 1) Push and hold NET GROSS or FIELD and ...
AWT 640 Settings for Serial RD4100
If Sign Does Not Work Follow These Instructions Avery Weigh Tronix serial port for 640 1906-0409 - 4” RD4100 1000-8890-adapter cable also required 1) Push and hold the HOLD/MENU key until it says “SETPAS”. (*Note: If the indicator just sits there and ...
Settings for 640 to Remote Displays
Settings for 640 to XLR Remote Displays Press and hold the HOLD/MENU button for three beeps then release. Enter "640". Use RM to increase the displayed value and M+ to decrease it. Press the HOLD/MENU button to move one digit to the left. Press ...