Dual Scale Mode

Dual Scale Mode

Enabling Dual Scale Mode

  1. To enable dual scale mode the POINT must be updated to firmware 2.1.12 or later
  2. Go to "Choose Mode" and select Dual Scale, then click Select.

Configuring Dual Scales

  1. Calibration Weight, Scale Capacity, Display Count, and Filter Sample Depth are set independently for each scale channel
  2. Parameters with a prefix of "C1" correspond to channel 1 on the left side of the screen (Left DT6 Receptacle)
  3. Parameters with a prefix of "C0" correspond to channel 0 on the right side of the screen (Right DT6 Receptacle)

Operating The POINT Indicator in Dual Scale Mode

  1. Channel 1 appears on the left side of the screen and Channel 0 appears on the right
  2. A box around the weight indicates which scale channel is currently selected for control
  3. A short tap on the power button switches which scale channel is selected
  4. Start, Stop, Hold, and Zero functions initiated from the indicator buttons affect only the scale channel currently selected for control

ISOBUS VT

  1. If ISOBUS is enabled while in Dual Scale Mode, the Gross and Tare weights for both scale channels will appear simultaneously on the VT display