Lock-on Start Time

The delay (in seconds) before starting the weight sampling after activation of lock-on detection.

Permissible Range: 1 - 10 seconds.

2 is the recommended minimum.  Increase if “weighing” starts before the animal is completely on the scale. Default is 4.

Lock-on Average Time

The Duration (in seconds) for which the weight is averaged to compute the lock-on value.

Permissible Range: 1 - 10 seconds.

2 is the recommended minimum.  Increase if weight is inconsistent due to animal movement.  Default is 3.

Lock-on Release Weight Percentage

The Percentage of lock-on weight at which the lock is released. For example, if the lock-on weight was recorded as 1200 lbs and the Lock-on Release Weight Percentage is 50%, then when the scale weight drops below 600 lbs, the lock-on will be released and the state will return to tracking.

Permissible Range: 10 - 90 percent.  

Higher values allow for slightly faster zeroing but may cause loss of LOCK-ON before the animal has left the chute. Recommended max is ~60. Default is 50.

Zero Track Duration

The Duration (in seconds) over which the zero track feature checks for signal stability. A higher value results in a slower activation of zero tracking, but is more immune to variations in the weight.

Permissible Range: 1 – 4

1.5 is the recommended minimum. Default is 1.5.

Zero Track Standard Deviation Limit

The maximum standard deviation of weight as a percentage of scale capacity at which the zero track zeros the scale. A lower value requires a more stable weight value before the zero is performed.

Permissible Range: 0.01 – 1 

Use lowest value possible. If Zero Track is not working, increase value. Default is 0.1

Zero Track Maximum Weight

The Maximum weight in pounds which under which the zero track feature is active.

Permissible Range: 0 - 50 Lbs

~25 is recommended, adjust as needed. Default is 25.


Lock-on detection starts at 1% of scale capacity

    • Related Articles

    • Livestock Chute Scale Screens On POINT

      Livestock Chute Scale Screens On POINT Setting a POINT to Chute Mode changes it's operation to better suit weighing livestock.  During the process of weighing an animal, POINT will cycle through several different screens. READY The READY screen is ...
    • Scale-Tec POINT Livestock Settings

      Lock-on Start Time Delay (in seconds) before starting the weight sampling after activation of lock-on detection. Permissible Range: 1 - 10 seconds. 2 is the recommended minimum.  Increase if “weighing” starts before animal is completely on scale. ...
    • POINT Device Settings: Adjusting an Individual Setting (iOS)

      Settings POINT supports a whole new method to making settings changes on the hardware.   You may be familiar with other brands of indicator which require a button sequence and timing sequence to access settings menus.   With POINT, all of that goes ...
    • Ordering POINT for Livestock Scales

      Ordering POINT for Livestock Scales Answer the questions below to determine which conversion kit is necessary to add a POINT scale to your livestock chute. 1) Does the chute already have a scale? Yes (proceed to question 2A) No ​(Kit - 7300137RI & ...
    • Custom Settings Profile: Creating and Saving a Custom Profile (Android)

      Creating a Custom Profile POINT was made to easily switch configurations between multiple scale types and applications.  A great example of this would be using POINT on your grain cart in the fall and then using it in the spring on your seed tender.  ...