If indicator has keypad please use Direct Access Numbers
1) Push and hold NET GROSS or FIELD and ON until Indicator reads, press select or net for Menu’s 1,2,3,4,5, etc.
2) Press SELECT or NET GROSS or FIELD until it says Menu 2.
3) Press ON until RMDISP appears.
4) Press SELECT or NET GROSS or FIELD until it says EZ2.
5) Continue to push ON repeatedly until it says exit.
6) Press ON once to go back to weighing mode.
1) Key in 234.
2) Press SELECT until EZ2 appears.
3) Press ENTER.
1) Key in 2401.
2) Press Select until EZ2 appears.
3) Press Enter.