Required Digi-Star Indicator settings for correct RD4100/Remote Display Operation

Required Digi-Star Indicator Settings for Correct RD4100/Remote Display Operation

Digi-Star Indicator RD-4100 Settings/Remote Port


Remote Port Instructions Only

If indicator has keypad please use Direct Access Numbers


USE THE METHOD BELOW IF THE INDICATOR IS AN EZ2000, EZ2400, OR EZ2500

1)      Push and hold NET GROSS or FIELD and ON until Indicator reads, press select or net for Menu’s 1,2,3,4,5, etc.

2)      Press SELECT or NET GROSS or FIELD until it says Menu 2.

3)      Press ON until RMDISP appears.

4)      Press SELECT or NET GROSS or FIELD until it says EZ2.

5)      Continue to push ON repeatedly until it says exit.

6)      Press ON once to go back to weighing mode.


USE THE METHOD BELOW IF THE INDICATOR IS AN EZ3200, EZ3400, EZ3600, EZ4600, OR GT460

1)       Key in 234.

2)      Press SELECT until EZ2 appears.

3)      Press ENTER.


USE THE METHOD BELOW IF THE INDICATOR IS AN EZ2810, EZ3410, EZ3610, OR GT560

1)       Key in 2401.

2)      Press Select until EZ2 appears.

3)      Press Enter.

 

USE THE METHOD BELOW IF THE INDICATOR IS AN EZ150, EZ210, OR EZ320 ( This does NOT work on the very first EZ150, EZ210, and EZ320 indicators made.  The serial number split is unknown.  So if your indicator wont do this, then it is too old. )


1)      Hold "Net/Gross" and "On" until you hear a beep

2)      Press "On" repeatedly to cycle through each selection until the scale reads "Press On to Exit"

3)
      Press "Tare" to enter the Set Up Menu

4)
      Press "On" twice or until you see "REMOTE"

5)
      Press "Net/Gross" to set REMOTE to "EZR"

6)
      Press "On" repeatedly until the scale returns to the weigh screen