Changing settings within the indicator for correct RD4100 remote operation

Required Digi-star Indicator Settings for Correct RD4100/Serial Display Operation.



Required Digi-star Indicator Settings for Correct RD4100/Serial Display Operation.Serial Port Instructions only

USE THE METHOD BELOW IF THE INDICATOR IS A EZ400, GT400, OR EZ2500V

                                1)      Push and hold NET GROSS or FIELD and ON until it scrolls, press select or net for Menu’s 1,2,3,4,5, etc.

                    2)     Press NET GROSS or FIELD or SELECT until Menu 2 appears
                    3)     Press ON until SCOREM appears.
                    4)     Press NET GROSS or FIELD or SELECT until 22 comes up.
                    5)     Press ON so COMIN appears.
                    6)     Press NET GROSS or FIELD or SELECT until EZ2CMD appears.
                    7)     Press ON repeatedly until Press select Menu appears. 
                    8)     Press NET GROSS or FIELD or SELECT until Exit appears.
                                9)     Press ON once more to return to weight mode.

USE THE METHOD BELOW IF THE INDICATOR IS A GT460, EZ3600, OR EZ4600

1)      Key in 213.

2)     Press SELECT until the number 22 appears.

3)     Press ENTER.

4)     Key in 215.

5)     Press SELECT until EZ2CMD appears.

6)     Press ENTER.


USE THE METHOD BELOW IF THE INDICATOR IS A GT560, EZ2810, EZ3410, OR EZ3610

1)      Key in 2101.

2)     Press select, continue to press Select until 2 is displayed.

3)     Press enter.

4)     Key in 2201.

5)     Press select, and continue to press Select until 9600 is displayed.

6)     Press enter.

    7)     Key in 5006.
    8)     Press select until COM1 is shown.

9)     Press enter.