Changing settings within the indicator for correct RD4100 remote operation

Required Digi-star Indicator Settings for Correct RD4100/Serial Display Operation.



Required Digi-star Indicator Settings for Correct RD4100/Serial Display Operation.Serial Port Instructions only

USE THE METHOD BELOW IF THE INDICATOR IS A EZ400, GT400, OR EZ2500V

                                1)      Push and hold NET GROSS or FIELD and ON until it scrolls, press select or net for Menu’s 1,2,3,4,5, etc.

                    2)     Press NET GROSS or FIELD or SELECT until Menu 2 appears
                    3)     Press ON until SCOREM appears.
                    4)     Press NET GROSS or FIELD or SELECT until 22 comes up.
                    5)     Press ON so COMIN appears.
                    6)     Press NET GROSS or FIELD or SELECT until EZ2CMD appears.
                    7)     Press ON repeatedly until Press select Menu appears. 
                    8)     Press NET GROSS or FIELD or SELECT until Exit appears.
                                9)     Press ON once more to return to weight mode.

USE THE METHOD BELOW IF THE INDICATOR IS A GT460, EZ3600, OR EZ4600

1)      Key in 213.

2)     Press SELECT until the number 22 appears.

3)     Press ENTER.

4)     Key in 215.

5)     Press SELECT until EZ2CMD appears.

6)     Press ENTER.


USE THE METHOD BELOW IF THE INDICATOR IS A GT560, EZ2810, EZ3410, OR EZ3610

1)      Key in 2101.

2)     Press select, continue to press Select until 2 is displayed.

3)     Press enter.

4)     Key in 2201.

5)     Press select, and continue to press Select until 9600 is displayed.

6)     Press enter.

    7)     Key in 5006.
    8)     Press select until COM1 is shown.

9)     Press enter.


    • Related Articles

    • Required Digi-Star Indicator Settings for Correct RD4100/Remote Display Operation

      Digi-Star Indicator RD-4100 Settings/Remote Port Remote Port Instructions Only If indicator has keypad please use Direct Access Numbers USE THE METHOD BELOW IF THE INDICATOR IS AN EZ2000, EZ2400, OR EZ2500 1)      Push and hold NET GROSS or FIELD and ...
    • Required Digi-Star Indicator Settings for Correct RD4100/J904 Serial Display Operation (Power Y-Harness Only)

      If Sign Does Not Work Follow These Instructions Digi-Star J-904 Serial Port Indicators (Power Y-Harness Only)  1906-0404 - 4” RD4100 USE THE METHOD BELOW IF THE INDICATOR IS AN EZ400, EZ2000, OR EZ2400 Push and hold NET GROSS and ON until it scrolls, ...
    • AWT 640 Settings for Serial RD4100

      If Sign Does Not Work Follow These Instructions Avery Weigh Tronix serial port for 640 1906-0409 - 4” RD4100 1000-8890-adapter cable also required 1) Push and hold the HOLD/MENU key until it says “SETPAS”. (*Note: If the indicator just sits there and ...
    • Settings for 640 to Remote Displays

      Settings for 640 to XLR Remote Displays Press and hold the HOLD/MENU button for three beeps then release. Enter "640". Use RM to increase the displayed value and M+ to decrease it. Press the HOLD/MENU button to move one digit to the left. Press ...