Settings for 640 to XLR Remote Displays
Press and hold the HOLD/MENU button for three beeps then release.
Enter "640". Use RM to increase the displayed value and M+ to decrease it. Press the HOLD/MENU button to move one digit to the left.
Press PRINT/SELECT to accept and "640" will be shown again.
Press PRINT/SELECT and CONFIG will be displayed
Press HOLD/MENU key repeatedly until RS232 is shown
Press PRINT/SELECT
PORT 1 is displayed.
Press PRINT/SELECT
BAUD is shown
- Press HOLD/MENU to get 9600 is displayed
Press PRINT/SELECT
- BAUD is displayed.
Press the HOLD/MENU
PARITY is shown
- Press PRINT/SELECT
- Press HOLD/MENU to get to NONE
Press PRINT/SELECT
PARITY is shown.
Press the HOLD/MENU key
HAND is shown.
- Press PRINT/SELECT
- Press HOLD/MENU to NONE
- Press PRINT/SELECT
HAND is shown.
Press the HOLD/MENU key
LAYOUT is shown.
- Press PRINT/SELECT
- Press HOLD/MENU to REMOTE
Press PRINT/SELECT
LAYOUT is shown
Press G/N key once
Press the HOLD/MENU key to display PORT 2
Repeat steps 6 through 13 under PORT 2
Press the G/N key repeatedly to return to the gross weighing mode.