EatonFunction | J-Box Cable (DS) | Load Cell 1 | Load Cell 2 | Load Cell 3 | Load Cell 4 |
| +Sig | White | White |
| White |
|
-Sig | Green |
| White |
| White |
+Ex | Red | Black | Red | Black | Red |
-Ex | Black | Red | Black | Red | Black |
Shield | Shield | Green | Green | Green | Green |
AWT 4-PinFunction | J-Box Cable (DS) | Load Cell 1 | Load Cell 2 | Load Cell 3 | Load Cell 4 |
| +Sig | White | Black |
| Black |
|
-Sig | Green |
| Black |
| Black |
+Ex | Red | White | Red | White | Red |
-Ex | Black | Red | White | Red | White |
Shield | Shield | Green | Green | Green | Green |
The above charts show which load cell wires should be paired with each wire from the J-box cable.
For example: When using eaton load cells the white J-box cable wire will have two white wires connected to it. The green J-box cable wire will have the other two white wires connected to it. The red wire will have two reds and two blacks connected to it. The black wire will have two reds and two blacks connected to it. Shield wire will have all four green load cell wires connected to it.