Avery Weigh-Tronix
Changing Config Number in Model 640
Press and hold the "Hold/Menu" button for three beeps then release. Enter "640". Use "RM" to increase the displayed value and "M+" to decrease it. Press the "Hold/Menu" button to move one digit to the left. Press "Print/Select" to accept and "640" ...
Avery Weigh-Tronix 1040 Indicator calibration
Push and hold the MENU key until it says “SETPAS”. (*Note: If the indicator just sits there and beeps after 3-4 seconds, let go of the MENU key, at that point “SETPAS” should appear) Type 1040 Once “1040” is on the screen press SELECT. (*At this ...
Adjusting SPAN on Model 615
Adjusting SPAN on Model 615 This is method can only be used if calibration is already within 10%. For larger adjustments see - https://support.scale-tec.com/portal/en/kb/articles/calibrating-a-model-615-indicator-using-a-custom-sensitivity 1. With ...
Libra/iForeman Calibration and Operation
Libra/iForeman Connecting the APP to the I-Foreman/Libra Device: I) Open APP and go to SETTINGS tab. 2) Push the + button on the top left of APP. 3) Once the APP finds the device type in the Cart Name, then push Okay. Calibrating the ...
Calibrating an AWT 700E
See the attached service manual Config number starts on page 2 Custom sensitivity starts on page 6 Span starts on page 9
Avery Weigh-Tronix Load Cell Calibration Numbers
The reading @ 0.4mV/V can be used as the Calibration number for a Digi-star indicator, or the Custom number on a Weigh-tronix indicator.
Calibrating a Model 1015 Indicator Using a Custom Sensitivity
Calibrating a Model 1015 Indicator using a Custom Sensitivity This is the best method to calibrate a 1015 if using any loads cells with a known output. 1. Type in 1015 2. Hold the hidden E key for two seconds until 1015E is displayed. 3. ...
Entering a Configuration Number on a Model 1015 Indicator
Entering a Configuration Number on a Model 1015 Indicator This is the best method to calibrate a 1015 if using AWT loads cells of a known calibration diameter. 1. Type in 1015 2. Hold the hidden E key for two seconds until 1015E is ...
Calibrating a Model 915 Indicator using a Custom Sensitivity
Calibrating a Model 915 Indicator using a Custom Sensitivity This is the best method to calibrate a 915 if using any loads cells with a known output. 1. Type in 915 2. Hold the hidden E key for two seconds until 915E is displayed. 3. ...
Entering a Configuration Number on a Model 915 Indicator
Entering a Configuration Number on a Model 915 Indicator This is the best method to calibrate a 915 if using AWT loads cells of a known calibration diameter. 1. Type in 915 2. Hold the hidden E key for two seconds until 915E is displayed. ...
Calibrating a Model 715 Indicator Using a Custom Sensitivity
Calibrating a Model 715 Indicator using a Custom Sensitivity This is the best method to calibrate a 715 if using any loads cells with a known output. 1. Type in 715 2. Hold the hidden E key for two seconds until 715E is displayed. 3. ...
Entering a Configuration Number on a Model 715 Indicator
Entering a Configuration Number on a Model 715 Indicator This is the best method to calibrate a 715 if using AWT loads cells of a known calibration diameter. 1. Type in 715 2. Hold the hidden E key for two seconds until 715E is displayed. ...
Calibrating a Model 615 Indicator Using a Custom Sensitivity
Calibrating a Model 615 Indicator using a Custom Sensitivity This is the best method to calibrate a 615 if using any loads cells with a known output. 1. Press the hidden programming key for 5 seconds until "615" is displayed. Some Model 615's ...
Entering a Configuration Number on a Model 615 Indicator
Entering a Configuration Number on a Model 615 Indicator This is the best method to calibrate a 615 if using AWT loads cells of a known calibration diameter. 1. Press the hidden programming key for 5 seconds until "615" is displayed. Some ...
Using Span to Fine Tune the Calibration on a 640
Using Span to Fine Tune the Calibration on a 640 Span should only be used for relatively small calibration adjustments of 10% or less Press and hold the "Hold/Menu" button for three beeps then release. Enter "640". Use "RM" to increase the displayed ...
Avery Weigh-Tronix 640 Indicator Calibration
Watch this video to calibrate your indicator. Press and hold the "Hold/Menu" button for three beeps then release. Enter "640". Use "RM" to increase the displayed value and "M+" to decrease it. Press the "Hold/Menu" button to move one digit to the ...