Entering a Configuration Number on a Model 715 Indicator

Entering a Configuration Number on a Model 715 Indicator

Entering a Configuration Number on a Model 715 Indicator


This is the best method to calibrate a 715 if using AWT loads cells of a known calibration diameter.


1.      Type in 715
2.      Hold the hidden E key for two seconds until 715E is displayed.

3.      Determine the new configuration number using the tables below.
      a.      Find the desired increment size and capacity (Calibration Diameter) in Table 2 to determine the first three digits of the config number. 




      b.      The fourth digit determines the Warning Alarm Factor.  If you are not using an alarm, use 0.  The Warning Alarm Factor is calculated by dividing the alarm weight by the increments.


      c.      The fifth digit determines the units used by the scale and whether or not Auto Hold is turned on.  Use 0 for most applications.


5. Type in the new Configuration number.
6. Press the hidden E key, E is displayed.
7. Press LOAD/UNLOAD, the new configuration number is displayed again.
8. Press GROSS to return to Gross weighing mode.


    • Related Articles

    • Entering a Configuration Number on a Model 915 Indicator

      Entering a Configuration Number on a Model 915 Indicator This is the best method to calibrate a 915 if using AWT loads cells of a known calibration diameter. 1.      Type in 915 2.      Hold the hidden E key for two seconds until 915E is displayed. ...
    • Entering a Configuration Number on a Model 615 Indicator

      Entering a Configuration Number on a Model 615 Indicator This is the best method to calibrate a 615 if using AWT loads cells of a known calibration diameter. 1.      Press the hidden programming key for 5 seconds until "615" is displayed.    Some ...
    • Entering a Configuration Number on a Model 1015 Indicator

      Entering a Configuration Number on a Model 1015 Indicator This is the best method to calibrate a 1015 if using AWT loads cells of a known calibration diameter. 1.      Type in 1015 2.      Hold the hidden E key for two seconds until 1015E is ...
    • Changing Config Number in Model 640

      Press and hold the "Hold/Menu" button for three beeps then release. Enter "640".  Use "RM" to increase the displayed value and "M+" to decrease it.  Press the "Hold/Menu" button to move one digit to the left. Press "Print/Select" to accept and "640" ...
    • Calibrating a Model 1015 Indicator Using a Custom Sensitivity

      Calibrating a Model 1015 Indicator using a Custom Sensitivity This is the best method to calibrate a 1015 if using any loads cells with a known output. 1.      Type in 1015 2.      Hold the hidden E key for two seconds until 1015E is displayed. 3.    ...